Kennwerte Flächenelement REI30
Höhe LIGNATUR-Flächenelement:
An = 70`990 mm2/m1
Iy = 130.3 mm4/m1 * 106
g = 33 kg/m2
Rv,z,k = 28 kN/m1
Rm,y,k = 52.1 kNm/m1
Rv,z,d,SIA = 21 kN/m1
Rm,y,d,SIA = 30.4 kNm/m1
An = 74`090 mm2/m1
Iy = 195.3 mm4/m1 * 106
g = 35 kg/m2
Rv,z,k = 33 kN/m1
Rm,y,k = 66.9 kNm/m1
Rv,z,d,SIA = 25 kN/m1
Rm,y,d,SIA = 39.1 kNm/m1
An = 77`190 mm2/m1
Iy = 275.1 mm4/m1 * 106
g = 36 kg/m2
Rv,z,k = 39 kN/m1
Rm,y,k = 82.5 kNm/m1
Rv,z,d,SIA = 29 kN/m1
Rm,y,d,SIA = 48.1 kNm/m1
An = 80`290 mm2/m1
Iy = 370.3 mm4/m1 * 106
g = 38 kg/m2
Rv,z,k = 45 kN/m1
Rm,y,k = 98.7 kNm/m1
Rv,z,d,SIA = 33 kN/m1
Rm,y,d,SIA = 57.6 kNm/m1
An = 83`390 mm2/m1
Iy = 481.6 mm4/m1 * 106
g = 39 kg/m2
Rv,z,k = 50 kN/m1
Rm,y,k = 115.6 kNm/m1
Rv,z,d,SIA = 37 kN/m1
Rm,y,d,SIA = 67.4 kNm/m1
An = 86`490 mm2/m1
Iy = 609.6 mm4/m1 * 106
g = 41 kg/m2
Rv,z,k = 55 kN/m1
Rm,y,k = 133.0 kNm/m1
Rv,z,d,SIA = 42 kN/m1
Rm,y,d,SIA = 77.6 kNm/m1
An = 89`590 mm2/m1
Iy = 754.9 mm4/m1 * 106
g = 42 kg/m2
Rv,z,k = 61 kN/m1
Rm,y,k = 151.0 kNm/m1
Rv,z,d,SIA = 46 kN/m1
Rm,y,d,SIA = 88.1 kNm/m1
An = 95`790 mm2/m1
Iy = 1`099.8 mm4/m1 * 106
g = 45 kg/m2
Rv,z,k = 71 kN/m1
Rm,y,k = 188.5 kNm/m1
Rv,z,d,SIA = 53 kN/m1
Rm,y,d,SIA = 110.0 kNm/m1
An = 101`990 mm2/m1
Iy = 1`521.4 mm4/m1 * 106
g = 48 kg/m2
Rv,z,k = 82 kN/m1
Rm,y,k = 228.2 kNm/m1
Rv,z,d,SIA = 61 kN/m1
Rm,y,d,SIA = 133.1 kNm/m1
An = 123`400 mm2/m1
Iy = 2`324.2 mm4/m1 * 106
g = 58 kg/m2
Rv,z,k = 92 kN/m1
Rm,y,k = 312.3 kNm/m1
Rv,z,d,SIA = 69 kN/m1
Rm,y,d,SIA = 182.2 kNm/m1
An = 140`585 mm2/m1
Iy = 2`621.4 mm4/m1 * 106
g = 66 kg/m2
Rv,z,k = 100 kN/m1
Rm,y,k = 310.1 kNm/m1
Rv,z,d,SIA = 75 kN/m1
Rm,y,d,SIA = 180.9 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
An = 146`785 mm2/m1
Iy = 3`302.7 mm4/m1 * 106
g = 69 kg/m2
Rv,z,k = 110 kN/m1
Rm,y,k = 355.8 kNm/m1
Rv,z,d,SIA = 83 kN/m1
Rm,y,d,SIA = 207.6 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
An = 152`985 mm2/m1
Iy = 4`080.5 mm4/m1 * 106
g = 72 kg/m2
Rv,z,k = 120 kN/m1
Rm,y,k = 403.6 kNm/m1
Rv,z,d,SIA = 90 kN/m1
Rm,y,d,SIA = 235.4 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
Kennwerte Flächenelement REI60
Höhe LIGNATUR-Flächenelement:
An = 105`075 mm2/m1
Iy = 299.2 mm4/m1 * 106
g = 49 kg/m2
Rv,z,k = 37 kN/m1
Rm,y,k = 81.0 kNm/m1
Rv,z,d,SIA = 28 kN/m1
Rm,y,d,SIA = 47.3 kNm/m1
An = 108`175 mm2/m1
Iy = 410.2 mm4/m1 * 106
g = 51 kg/m2
Rv,z,k = 42 kN/m1
Rm,y,k = 97.5 kNm/m1
Rv,z,d,SIA = 31 kN/m1
Rm,y,d,SIA = 56.9 kNm/m1
An = 111`275 mm2/m1
Iy = 541.7 mm4/m1 * 106
g = 52 kg/m2
Rv,z,k = 47 kN/m1
Rm,y,k = 114.9 kNm/m1
Rv,z,d,SIA = 35 kN/m1
Rm,y,d,SIA = 67.0 kNm/m1
An = 114`375 mm2/m1
Iy = 694.5 mm4/m1 * 106
g = 54 kg/m2
Rv,z,k = 53 kN/m1
Rm,y,k = 133.1 kNm/m1
Rv,z,d,SIA = 39 kN/m1
Rm,y,d,SIA = 77.6 kNm/m1
An = 117`475 mm2/m1
Iy = 869.2 mm4/m1 * 106
g = 55 kg/m2
Rv,z,k = 58 kN/m1
Rm,y,k = 152.0 kNm/m1
Rv,z,d,SIA = 43 kN/m1
Rm,y,d,SIA = 88.7 kNm/m1
An = 123`675 mm2/m1
Iy = 1`287.1 mm4/m1 * 106
g = 58 kg/m2
Rv,z,k = 69 kN/m1
Rm,y,k = 192.0 kNm/m1
Rv,z,d,SIA = 51 kN/m1
Rm,y,d,SIA = 112.0 kNm/m1
An = 129`875 mm2/m1
Iy = 1`801.0 mm4/m1 * 106
g = 61 kg/m2
Rv,z,k = 79 kN/m1
Rm,y,k = 234.7 kNm/m1
Rv,z,d,SIA = 59 kN/m1
Rm,y,d,SIA = 136.9 kNm/m1
An = 158`890 mm2/m1
Iy = 2`737.7 mm4/m1 * 106
g = 75 kg/m2
Rv,z,k = 88 kN/m1
Rm,y,k = 318.1 kNm/m1
Rv,z,d,SIA = 66 kN/m1
Rm,y,d,SIA = 185.5 kNm/m1
An = 168`470 mm2/m1
Iy = 3`144.8 mm4/m1 * 106
g = 79 kg/m2
Rv,z,k = 99 kN/m1
Rm,y,k = 331.5 kNm/m1
Rv,z,d,SIA = 74 kN/m1
Rm,y,d,SIA = 193.4 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
An = 174`670 mm2/m1
Iy = 3`980.4 mm4/m1 * 106
g = 82 kg/m2
Rv,z,k = 109 kN/m1
Rm,y,k = 382.3 kNm/m1
Rv,z,d,SIA = 82 kN/m1
Rm,y,d,SIA = 223.0 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
An = 180`870 mm2/m1
Iy = 4`933.1 mm4/m1 * 106
g = 85 kg/m2
Rv,z,k = 119 kN/m1
Rm,y,k = 435.4 kNm/m1
Rv,z,d,SIA = 89 kN/m1
Rm,y,d,SIA = 254.0 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
Kennwerte Flächenelement REI90
Höhe LIGNATUR-Flächenelement:
An = 134`090 mm2/m1
Iy = 589.9 mm4/m1 * 106
g = 63 kg/m2
Rv,z,k = 46 kN/m1
Rm,y,k = 128.3 kNm/m1
Rv,z,d,SIA = 34 kN/m1
Rm,y,d,SIA = 74.9 kNm/m1
An = 137`190 mm2/m1
Iy = 762.5 mm4/m1 * 106
g = 64 kg/m2
Rv,z,k = 51 kN/m1
Rm,y,k = 149.2 kNm/m1
Rv,z,d,SIA = 38 kN/m1
Rm,y,d,SIA = 87.0 kNm/m1
An = 140`290 mm2/m1
Iy = 961.1 mm4/m1 * 106
g = 66 kg/m2
Rv,z,k = 56 kN/m1
Rm,y,k = 171.0 kNm/m1
Rv,z,d,SIA = 42 kN/m1
Rm,y,d,SIA = 99.7 kNm/m1
An = 146`490 mm2/m1
Iy = 1`439.0 mm4/m1 * 106
g = 69 kg/m2
Rv,z,k = 67 kN/m1
Rm,y,k = 217.0 kNm/m1
Rv,z,d,SIA = 50 kN/m1
Rm,y,d,SIA = 126.6 kNm/m1
An = 152`690 mm2/m1
Iy = 2`029.4 mm4/m1 * 106
g = 72 kg/m2
Rv,z,k = 78 kN/m1
Rm,y,k = 266.1 kNm/m1
Rv,z,d,SIA = 58 kN/m1
Rm,y,d,SIA = 155.2 kNm/m1
An = 158`890 mm2/m1
Iy = 2`737.7 mm4/m1 * 106
g = 75 kg/m2
Rv,z,k = 88 kN/m1
Rm,y,k = 318.1 kNm/m1
Rv,z,d,SIA = 66 kN/m1
Rm,y,d,SIA = 185.5 kNm/m1
An = 198`890 mm2/m1
Iy = 3`576.7 mm4/m1 * 106
g = 93 kg/m2
Rv,z,k = 97 kN/m1
Rm,y,k = 376.2 kNm/m1
Rv,z,d,SIA = 73 kN/m1
Rm,y,d,SIA = 219.4 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
An = 205`090 mm2/m1
Iy = 4`539.1 mm4/m1 * 106
g = 96 kg/m2
Rv,z,k = 108 kN/m1
Rm,y,k = 434.3 kNm/m1
Rv,z,d,SIA = 81 kN/m1
Rm,y,d,SIA = 253.4 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
An = 211`290 mm2/m1
Iy = 5`635.9 mm4/m1 * 106
g = 99 kg/m2
Rv,z,k = 118 kN/m1
Rm,y,k = 495.0 kNm/m1
Rv,z,d,SIA = 88 kN/m1
Rm,y,d,SIA = 288.7 kNm/m1
* Ausführung nur nach positiver Absprache mit Lignatur
Kennwerte Kastenelement REI30
Höhe LIGNATUR-Kastenelement:
An = 80`560 mm2/m1
Iy = 132.9 mm4/m1 * 106
g = 38 kg/m2
Rv,z,k = 56 kN/m1
Rm,y,k = 53.2 kNm/m1
Rv,z,d,SIA = 42 kN/m1
Rm,y,d,SIA = 31 kNm/m1
An = 86`960 mm2/m1
Iy = 201.8 mm4/m1 * 106
g = 41 kg/m2
Rv,z,k = 67 kN/m1
Rm,y,k = 69.2 kNm/m1
Rv,z,d,SIA = 50 kN/m1
Rm,y,d,SIA = 40.4 kNm/m1
An = 93`360 mm2/m1
Iy = 288 mm4/m1 * 106
g = 44 kg/m2
Rv,z,k = 77 kN/m1
Rm,y,k = 86.4 kNm/m1
Rv,z,d,SIA = 58 kN/m1
Rm,y,d,SIA = 50.4 kNm/m1
An = 99`760 mm2/m1
Iy = 392.9 mm4/m1 * 106
g = 47 kg/m2
Rv,z,k = 88 kN/m1
Rm,y,k = 104.8 kNm/m1
Rv,z,d,SIA = 66 kN/m1
Rm,y,d,SIA = 61.1 kNm/m1
An = 106`160 mm2/m1
Iy = 517.7 mm4/m1 * 106
g = 50 kg/m2
Rv,z,k = 98 kN/m1
Rm,y,k = 124.3 kNm/m1
Rv,z,d,SIA = 73 kN/m1
Rm,y,d,SIA = 72.5 kNm/m1
An = 112`560 mm2/m1
Iy = 663.8 mm4/m1 * 106
g = 53 kg/m2
Rv,z,k = 108 kN/m1
Rm,y,k = 144.8 kNm/m1
Rv,z,d,SIA = 81 kN/m1
Rm,y,d,SIA = 84.5 kNm/m1
An = 118`960 mm2/m1
Iy = 832.4 mm4/m1 * 106
g = 56 kg/m2
Rv,z,k = 118 kN/m1
Rm,y,k = 166.5 kNm/m1
Rv,z,d,SIA = 89 kN/m1
Rm,y,d,SIA = 97.1 kNm/m1
An = 125`360 mm2/m1
Iy = 1`024.8 mm4/m1 * 106
g = 59 kg/m2
Rv,z,k = 128 kN/m1
Rm,y,k = 189.2 kNm/m1
Rv,z,d,SIA = 96 kN/m1
Rm,y,d,SIA = 110.4 kNm/m1
An = 131`760 mm2/m1
Iy = 1`242.3 mm4/m1 * 106
g = 62 kg/m2
Rv,z,k = 138 kN/m1
Rm,y,k = 213 kNm/m1
Rv,z,d,SIA = 104 kN/m1
Rm,y,d,SIA = 124.2 kNm/m1
Kennwerte Kastenelement REI60
Höhe LIGNATUR-Kastenelement:
An = 115`800 mm2/m1
Iy = 309.1 mm4/m1 * 106
g = 54 kg/m2
Rv,z,k = 74 kN/m1
Rm,y,k = 86 kNm/m1
Rv,z,d,SIA = 55 kN/m1
Rm,y,d,SIA = 50.2 kNm/m1
An = 122`200 mm2/m1
Iy = 428 mm4/m1 * 106
g = 57 kg/m2
Rv,z,k = 84 kN/m1
Rm,y,k = 105 kNm/m1
Rv,z,d,SIA = 63 kN/m1
Rm,y,d,SIA = 61.3 kNm/m1
An = 128`600 mm2/m1
Iy = 570.8 mm4/m1 * 106
g = 60 kg/m2
Rv,z,k = 94 kN/m1
Rm,y,k = 125.5 kNm/m1
Rv,z,d,SIA = 71 kN/m1
Rm,y,d,SIA = 73.2 kNm/m1
An = 135`00 mm2/m1
Iy = 738.9 mm4/m1 * 106
g = 63 kg/m2
Rv,z,k = 104 kN/m1
Rm,y,k = 147.3 kNm/m1
Rv,z,d,SIA = 78 kN/m1
Rm,y,d,SIA = 85.9 kNm/m1
An = 141`400 mm2/m1
Iy = 933.7 mm4/m1 * 106
g = 66 kg/m2
Rv,z,k = 115 kN/m1
Rm,y,k = 170.4 kNm/m1
Rv,z,d,SIA = 86 kN/m1
Rm,y,d,SIA = 99.4 kNm/m1
An = 147`800 mm2/m1
Iy = 1`156.4 mm4/m1 * 106
g = 69 kg/m2
Rv,z,k = 125 kN/m1
Rm,y,k = 194.7 kNm/m1
Rv,z,d,SIA = 94 kN/m1
Rm,y,d,SIA = 113.6 kNm/m1
An = 154`200 mm2/m1
Iy = 1`408.4 mm4/m1 * 106
g = 72 kg/m2
Rv,z,k = 135 kN/m1
Rm,y,k = 220.3 kNm/m1
Rv,z,d,SIA = 101 kN/m1
Rm,y,d,SIA = 128.5 kNm/m1
Dlubal Datenbank
Das Dlubal Statikprogramm bietet in Ihrer Datenbank viele LIGNATUR-Kennwerte zur statischen Bemessung unserer LIGNATUR-Decken- und Dachelemente. Besten Dank für die Aufnahme von LIGNATUR in die Dlubal Datenbank.
Ist Ihr gewählter LIGNATUR-Querschnitt nicht mit dabei? Kontaktieren Sie uns, wir nennen Ihnen die exakten Kennwerte.
beratung@lignatur.ch
Übersicht Formeln
Statische Verstärkung
Zur statischen Verstärkung führen wir die LIGNATUR-Elemente lokal massiv aus.
Statische Verstärkung am Auflager
Am Auflager empfehlen wir als erstes eine statische Verstärkung über drei Querstege in den Hohlkammern. Ist das nicht ausreichend, wird die Kammer lokal massiv ausgeführt. Meist reichen zwei Kammern.